Service:Compatible gases, steam, liquids or vapors.Wetted Materials:316L SS.Accuracy:±0.075% FS (@ 20°C).Rangeability:100:1 turn down.Stability:±0.125% FSO/yr.Temperature Limits:Process: -40 to 248°F (-40 to 120°C); Ambient: Without LCD -40 to 185°F (-40 to 85°C), With LCD -22 to 176°F (-30 to 80°C).Thermal Effect:±0.125% span/32°C.Power Requirements:11.9 to 45 VDC.Output Signal:4 to 20 mA / HART® Communication.Response Time:0.12 seconds.Damping Time:0.25 to 60 seconds.Loop Resistance:Operation: 0 to 1500 Ω HART® Communication: 250 to 500 Ω.Electrical Connection:Two 1/2″ female NPT conduit, screw terminal.Process Connections:1/2″ female NPT.Display:Optional: 5 digit LCD.Enclosure Rating:NEMA 4X (IP66) and explosion-proof for Class I, Div I Groups A, B, C and D.Weight:5.5 lb (2.5 kg).Agency Approvals:ATEX, CE, FM.